Description

  • ETL tested to be in compliance with standard safety, UL 2017, and Florida Building Commission Code requirements, per ETL listing number 3035022
  • Exceeds operational requirements of model barrier codes
  • Microprocessor controlled
  • Monitors entry to pool and spa areas
  • Options set by jumpers include closed or open loop, instant on or 7 second delay alarm, and 15 or 7 second adult shunt
  • Child resistant button guard built in
  • Surface or flush mount models
  • Capable of 2 year life with lithium battery
  • May be hard wired to remote 12 Volt 500 mA power source, applied voltage must not exceed 15 VDC
The new GRI Pool Access Alarm was designed as an aid in the prevention of unattended access to a pool/spa area by a small child. Monitoring all doors or windows with closed loop or open loop magnetic reed switches, the Pool Access Alarm will sound an alarm should anyone too small to manage the adult pass through feature attempt access to the pool/spa area. For maximum protection all movable openings should be protected in such a manner by the GRI Pool Access Alarm.

The PAA can be operated with an on-board 9 volt lithium battery or with a 12 volt externally supplied DC power source, in which case the battery will perform a back-up function should the externally supplied source fail for any reason. Both power sources have been designed to maintain a minimum sound pressure level of 85db at 10'. Should the battery voltage drop below 8.3 Volts, a low battery mode will be initiated and the unit will beep approximately every 50 seconds. Battery must be replaced at this time. It is suggested that some type of surge protection, such as the GRI CS-1 Current Sensor, be used between the power supply and the PAA.

Note: Unit will function at a minimum 5VDC at a very limited sounder volume. This power level is considered total battery failure.

Product Specification

  • ETL Listed
  • Hard Wired or Battery Operated (9V Lithium)
  • Multiple options set with jumper pins
  • Closed or Open Loop
  • Instant On or Seven Second Delay
  • 15 or 7 second adult shunt
  • Child resistant button guard built in
  • Remote Sounders, Remote Shunt Buttons & Remote Sounder/Shunt Button Combination available separately